Dynalco SST-2400H Speed Switch/Transmitter User Manual Page 1

Browse online or download User Manual for Relay Dynalco SST-2400H Speed Switch/Transmitter. Dynalco SST-2400H Speed Switch/Transmitter User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Transmitter

SST-2000 SeriesUniversal Speed Switch & SpeedTransmitterAn Operator’s Guide

Page 2 - Trademarks

OptionsEnclosures XP and NEMA rated enclosures are available.Open Pickup Relay 1 switches in the event of an open or disconnectedmagnetic pickup. Rela

Page 3 - Contents

Chapter2Installing the SST-2000A/H

Page 4

Mounting the unitThe SST-2000A/H is installed using standard hand tools. It is generally mounted in a panel or enclosure using standard practices.Abou

Page 5 - About your speed switch

Connecting Signal InputsConnecting a PG-278 PulserConnect signal source Common to terminal 6 on the SST-2000A/H. Connectsignal HI to terminals on the

Page 6 - Physical Dimensions

Chapter3Powering External Devices

Page 7 - Features

Powering an SPD-100, SPD-700, or other frequencyinstrumentsThe SST-2000A/H has a repeater output that can be used to power externalfrequency instrumen

Page 8 - Specifications

tConfirm the meter is properly connected to the SST-2000A/H. tUse a frequency generator (e.g. F-16) to apply full-scale frequencyto terminal 5 (HI) &a

Page 9 - Chapter 1

Powering Zero Velocity Pickups and Other LoadsThe regulated 14 Vdc supply brought out at terminals 11 (+) & 4 (–) has acapacity of 40 mA. This out

Page 10 - Getting Started

Driving an SPV-200 Solenoid Pneumatic ValveThe SPV -200 coil has a resistance of 50 Ω and requires 6 Vdc to trip.Switching the Regulated 14 Vdc Supply

Page 11 - Installing the SST-2000A/H

Chapter4Calibrating the Speed Switch

Page 12 - About Electrical Connections

CopyrightSpecifications and information herein are subject to change without notice.Dynalco Controls reserves the right to make changes to the equipme

Page 13 - Connecting Signal Inputs

Locating the programming switch instructions20Chapter 4Fig. 4-8 A full description of theprogramming switches and controlsis located under the top pla

Page 14 - Powering External Devices

Changing the full-scale input frequency rangeYou can set the standard full-scale frequency range from as low as 0–80 Hz to ashigh as 0–20 kHz.1 Remove

Page 15 - Connecting one DPM-105

Calibrating the SST-2000A/HYou must calibrate the SST-2000A/H if you have made a change in the full-scale frequency range (changed contacts to DIP swi

Page 16

23Calibrating the Speed SwitchFreq. Range(in kHz)Switch A ONPositionsFreq. Range(in Hz)0.08 - 0.10 1, 8 80 - 1000.10 - 0.13 2, 8 100 - 1300.13 - 0.17

Page 17 - Chapter 3

Calibrating the 4-20 mA Proportional OutputYou must calibrate the speed switch if the standard proportional output of 4 to 20 mA is changed to :t0–5 V

Page 18 - Switching 28 Vdc

Programming Set Points and RelaysRemove the top plate from the SST-2000A/H to reveal DIP switches B and C. Use DIP switches B and C to program relay s

Page 19 - Calibrating the Speed Switch

Set points 3 & 4 and selecting DPDT tripTHE EFFECT OF TURNING B SWITCHES ONTurn on B to...B1 LATCH set point 3 on alarmB2 ACTUATE relay 4 simultan

Page 20 - Chapter 4

Adjusting Signal SensitivityDesensitizing Standard InputsSignal sensitivity is factory set to 25 mVrms (about 35 mV peak or 70 mVpeak-to-peak) and sat

Page 21

Response TimeResponse time is the time required for the proportionaloutputs to change from 10% to 90% of the maximumcalibrated value for an instantane

Page 22 - Calibrating the SST-2000A/H

2 Apply the calculated set point frequency to terminals 5 (HI) &6 (COM). 3 Apply operating power to the SST-2000A/H. See lid of yourSST-2000A/H or

Page 23

ContentsChapter 1 Getting Started 1About your speed switch ...2Models...

Page 24

tan RPM indicator/tachometer operating from one of theproportional outputs of the SST-2000A/H:tan independent meter mounted elsewhere on or near the e

Page 25 - Resetting a latched relay

Verifying Set Point ValuesYou can view and adjust the set point values without having to run the engine.NOTE: The SST-2000A/H (no set points) does not

Page 26

Adjusting Set Point ValuesYou will need a 0–1 mA meter for this procedure. If a meter was supplied withthe speed switch, you can use it. Otherwise, yo

Page 27 - Adjusting Signal Sensitivity

IndexCcalibrating, 19, 21 - 23, 25, 27, 29,31commons, 10contact closure, 27CSAClass I, Div.2, Grp. D (Hseries), 4general certification (A series),

Page 28 - Response Time

Chapter1Getting Started

Page 29 - Engine Is Operating

About your speed switchThe SST-2000A/H series is a speed switch and signal transmitter that providesalarm set points for over- and underspeed control

Page 30

Physical Dimensions3Getting StartedFig. 1-1 Top and side view of the SST-2000A/H.Dimensions in inches and(centimeters).Special explosion proofhousings

Page 31 - Verifying Set Point Values

ModelsModelNo. Of Set Points3rd Party Certification(s)A series – standard relaysSST-2000A 0 CSA: general certification LR 92270ABS: type approvalCE: 8

Page 32 - Adjusting Set Point Values

SpecificationsElectricalInput SignalFrequencyRanget 0-20 kHz (standard) (field-adjustable)t 0-0.1 Hz (special order)t 0-80 Hz (special order)t 0-50K H

Page 33

RelaysLogic Field-programmable by switches for:t overspeed/underspeedt energize/de-energizet latch/auto-resett SPST/DPDT (2 DPDT set points maximum)A